DETAILS, FICTION AND ATS SOCOMEC

Details, Fiction and ATS Socomec

Details, Fiction and ATS Socomec

Blog Article

Charge-productive The ATyS C25 has an integrated DPS, for supplying the motorisation of your change, and can be doorway mounted, as a result there’s no require for an external DPS or display, lessening set up time and fees.

ATyS C65 is a complicated ATSE controller offering all of the capabilities with the ATyS C55 Using the addition of existing, electrical power & Strength monitoring, enhanced I/O ability and features, load shedding, lift Handle purpose, Electrical power backup, elevated amount of activities and alarms (measurement and mixture alarms) and DIRIS Digiware module compatibility.

Rapidly commissioning On First electrical power up, the ATyS C55’s sensible wizard will information the operator throughout the commissioning method.

ATyS C25 assure the automated or remotely controlled transfer from just one supply to another with fastened timers and thresholds.

Versatile Area saving The ATyS C25 controller may be mounted on possibly a DIN rail or to your panel doorway, supplying overall flexibility and optimising space.

Likelihood to established periodic genset startup Likelihood to set periodic genset startup ATyS p switches give added capabilities for upkeep. They incorporate a programmable genset commencing functionality which makes it possible for the beginning dates and running occasions to generally be configured.

These are meant for use in website reduced voltage power offer methods exactly where a short interruption from the load offer is acceptable through transfer.

They are really supposed to be used in reduced voltage electric power source systems exactly where a short interruption on the load offer is appropriate during transfer.

Recording of situations ATyS p switches allow productive checking within your installation due to timestamped celebration recording.

ATyS p are 3 or 4 pole automated transfer switches with constructive break indication. They include the many features provided by the ATyS t and g, along with functions suitable for electric power management and functions interaction.

Remote control interface Especially made for installations where by the item is enclosed, the remote interface displays solution standing about the front panel (D10) or displays and controls with entry to programming (D20).

Prices contains mounted fares, taxes & gratuity without having hidden fees. You are going to obtain confirmation within your scheduling by means of e-mail confirming your journey details.

Effortless Config Method program Configure your Socomec measuring and load breaking devices Program solution for any more rapidly, a lot more responsible and even more adaptable configuration within your electrical power checking system

Protected ATyS p M have both of those electrical and mechanical interlocks for the best possible protection. Additionally they function a good break indicator, confirming swap placement with dual mechanical indicators for increased protection.